LICHTENSTEIN


DynaMesh®-LICHTENSTEIN ve DynaMesh®-LICHTENSTEIN görünür implantlar, kasık fıtıklarının cerrahi tedavisi için tasarlanmıştır ve kasık bölgesindeki fıtık defekti alanındaki yumuşak dokuyu kalıcı olarak köprülemek ve güçlendirmek için kullanılır.


Paylaş

For example: inguinal hernia, left side

lichtenstein-detail

lichtenstein-elastische-sic

Varying Pore Size
The devices have areas with different pore sizes.

lichtenstein-tunnelbildung

Prefabricated Slit & Smooth Warp-Knitted Selvedges
The devices have a prefabricated slit with smooth warp-knitted selvedges, and they have tear propagation resistance [TR82].

lichtenstein-spezielle-wirk

Visibility & Handling
The colouring provides better intraoperative visibility and handling of the device.

[#] Reference “#” (see “References”)
[TR#] Internal test report (see “internal test report references”)
Limitations “A” animal trial, “B” bench test, “VIT” in-vitro trial, “P” published results based on the analysis of human mesh explants, “PB” published results mainly based on bench tests

When selecting the mesh size, ensure sufficient overlap!

DynaMesh®-LICHTENSTEIN 06 cm x 11 cm PV110611F1/F3/F5/F10
DynaMesh®-LICHTENSTEIN 7.5 cm x 15 cm PV110715F1/F3/F5/F10
DynaMesh®-LICHTENSTEIN 10 cm x 15 cm PV111015F1/F3/F5
DynaMesh®-LICHTENSTEIN visible 06 cm x 11 cm PV170611F3/F10
DynaMesh®-LICHTENSTEIN visible 7.5 cm x 15 cm PV170715F1/F3/F10
FX = X unit(s)/box (e.g. F3 = 3 unit(s)/box)
Can be used both for the right and the left side.

Product DynaMesh®-LICHTENSTEIN (1)
DynaMesh®-LICHTENSTEIN visible (2)
Surgical Treatment Inguinal Hernias
Surgical Approach Open
Surgical Technique Lichtenstein
Mesh Position Onlay (Anterior)
Fixation Sutures / Tacks / Tissue Adhesives*
Coloured Filaments Green (1) / Black (2)
Smooth Warp-Knitted Selvedges
gruene_punkte
Visible Technology
graue_punkte (1) / gruene_punkte (2)
Materials  – Polyvinylidene fluoride (PVDF) (CAS 24937-79-9) > 99% (w/w) (1) (2)
– Phthalocyanine green (CAS 1328-53-6) < 1% (w/w) (1)
– Triiron tetraoxide (CAS 1317-61-9) < 1% (w/w) (2)
Polymer (Monofilament) PVDF
Biocompatibility
gruene_punkte [TR1]
Ageing Resistance
gruene_punkte [2A, 5VIT, 27A, 52VIT, 93A, 101]
Tear Propagation Resistance
gruene_punkte [TR82]
Effective Porosity
gruene_punkte High effective porosity reduces inflammation and the risk of excessive scar formation. [103P, TR83]
Klinge’s Mesh Classification Class 1a [102P, TR83]
* Tissue adhesive can be used for fixation for direct or indirect inguinal hernias with a defect size of 1.5 cm to 3 cm (European Hernia Society Classification: M2 or L2).
gruene_punkte Applies to all product sizes
gaue_punkte Does not apply
[#] Reference “#” (see “References”)
[TR#] Internal test report (see “internal test report references”)
Limitations “A” animal trial, “B” bench test, “VIT” in-vitro trial,
“P” published results based on the analysis of human mesh explants,
“PB” published results mainly based on bench tests

DynaMesh® Catalogue

Download as PDF (english)