ENDOLAP


DynaMesh®-ENDOLAP ve DynaMesh®-ENDOLAP görünür implantlar, kasık veya femoral fıtıkların cerrahi tedavisi için tasarlanmıştır ve fıtık defekti alanında kasık bölgesindeki yumuşak dokuyu kalıcı olarak köprülemek ve güçlendirmek için kullanılır.


Paylaş

endolap_bild_01

Smooth Warp-Knitted Selvedges
The devices have smooth warp-knitted selvedges.

endolap_bild_02

Choice of Method
The devices must be placed by means of laparoscopic transabdominal preperitoneal (TAPP) or endoscopic totally extraperitoneal (TEP)1) hernia repair. The colouring provides better intraoperative visibility and handling of the device.


1) Image of surgery courtesy of Dr. A. Kuthe,
DRK-Krankenhaus Clementinenhaus, Hanover, Germany

endolap_bild_03

High Effective Porosity
The devices have a high effective porosity, which is known to reduce inflammation and the risk of excessive scar formation. [103P, TR23]

[#] Reference “#” (see “References”)
[TR#] Internal test report (see “internal test report references”)
Limitations “A” animal trial, “B” bench test, “VIT” in-vitro trial, “P” published results based on the analysis of human mesh explants, “PB” published results mainly based on bench tests

When selecting and cutting the device, sufficient defect overlap must be ensured to minimise the likelihood of the hernia recurring.

DynaMesh®-ENDOLAP 7.5 cm x 15 cm PV100715F1/F3
DynaMesh®-ENDOLAP 10 cm x 15 cm PV101015F1/F3/F10
DynaMesh®-ENDOLAP 12 cm x 15 cm PV101215F1/F3/F10
DynaMesh®-ENDOLAP 13 cm x 15 cm PV101315F1/F3
DynaMesh®-ENDOLAP 13 cm x 17 cm PV101317F1/F3/F10
DynaMesh®-ENDOLAP 15 cm x 15 cm PV101515F1/F3/F10
DynaMesh®-ENDOLAP visible 10 cm x 15 cm PV141015F1/F3/F10
DynaMesh®-ENDOLAP visible 15 cm x 15 cm PV141515F1/F3/F10
DynaMesh®-ENDOLAP visible 15 cm x 30 cm PV141530F1
FX = X unit(s)/box (e.g. F3 = 3 unit(s)/box)
Product DynaMesh®-ENDOLAP (1)
DynaMesh®-ENDOLAP visible (2)
Surgical Treatment Inguinal Hernias / Femoral Hernias
Surgical Approach Laparoscopic / Endoscopic
Surgical Technique TAPP / TEP
Mesh Position Preperitoneal (Posterior)
Fixation (None)* / Sutures / Tissue Adhesives / Tacks
Coloured Filaments Green
Smooth Warp-Knitted Selvedges
gruene_punkte
Visible Technology
graue_punkte (1) / gruene_punkte (2)
Materials  – Polyvinylidene fluoride (PVDF) (CAS 24937-79-9) > 99% (w/w) (1) (2)
– Phthalocyanine green (CAS 1328-53-6) < 1% (w/w) (1) (2)
– Triiron tetraoxide (CAS 1317-61-9) < 1% (w/w) (2)
Polymer (Monofilament) PVDF
Biocompatibility
gruene_punkte [TR1]
Ageing Resistance
gruene_punkte [2A, 5VIT, 27A, 52VIT, 93A, 101]
Tear Propagation Resistance
gruene_punkte [TR21]
Effective Porosity
gruene_punkte High effective porosity reduces inflammation and the risk of excessive scar formation. [103P, TR23]
Klinge’s Mesh Classification Class 1a [102P, TR23]
* Based on current knowledge, with the exception of large direct inguinal hernias (European
Hernia Society classification: M3), it appears possible to dispense with any form of fixation.
gruene_punkte Applies to all product sizes
gaue_punkte Does not apply
[#] Reference “#” (see “References”)
[TR#] Internal test report (see “internal test report references”)
Limitations “A” animal trial, “B” bench test, “VIT” in-vitro trial,
“P” published results based on the analysis of human mesh explants,
“PB” published results mainly based on bench tests

DynaMesh® Catalogue

Download as PDF (english)

Als pdf herunterladen (deutsch)


Diğer | Kasık Fıtığı | Fıtık İmplantları | DynaMesh


Deneyiminizi iyileştirmek için yasal düzenlemelere uygun çerezler (cookies) kullanıyoruz. Detaylı bilgiye Gizlilik ve Çerez Politikası sayfamızdan erişebilirsiniz.

Kabul Et!

Privacy Preferences

When you visit any website, it may store or retrieve information through your browser, usually in the form of cookies. Since we respect your right to privacy, you can choose not to permit data collection from certain types of services. However, not allowing these services may impact your experience.