Videos: DynaMesh®-PRP soft & DynaMesh®-PRP visible – Pectopexy
Posted: 17. June 2020 | 0 comments
						
								DynaMesh®-PRP yumuşak ve DynaMesh®-PRP görünür implantlar, apikal pelvik organ prolapsusuna yönelik cerrahi tedavinin bir parçası olarak köprüleme materyali olarak kullanılmak ve yumuşak dokuyu güçlendirmek üzere tasarlanmıştır.
Cerrahi teknik:

Pectopexy
Bilateral Fixation on the Pectineal Ligament
Fig. left:
Apical mesh repair following hysterectomy with DynaMesh®-PRP soft / visible (03 cm x 15 cm)

Pectopexy after vaginal/cervical stump prolapse:

Pectopexy after vaginal/cervical stump prolapse with concomitant cystocele and/or rectocele: (pulsion cystocele / rectocele)

Pectopexy after uterine prolapse with uterine preservation:

Pectopexy after uterine prolapse with uterine preservation:
| DynaMesh®-PRP soft | (1) 03 cm x 15 cm | PV540315F1/F3 | 
| DynaMesh®-PRP visible | (2) 03 cm x 15 cm | PV780315F1 | 
| DynaMesh®-PRP visible | (3) 03 cm x 18 cm | PV780318F1/F3 | 
| DynaMesh®-PRP visible) | (4) 17 cm x 15 cm | PV781715F1/F3 | 
| FX = X unit(s)/box (e.g. F3 = 3 unit(s)/box) | 
| Product | DynaMesh®-PRP soft 03 cm x 15 cm (1) DynaMesh®-PRP visible 03 cm x 15 cm (2) DynaMesh®-PRP visible 03 cm x 18 cm (3) DynaMesh®-PRP visible 17 cm x 15 cm (4)  | 
| Surgical Treatment | Apical Pelvic Organ Prolapse (Uterus / Vaginal Stump / Cervical Stump) | 
| Surgical Approach | Minimally Invasive / Open | 
| Surgical Technique | Pectopexy (1) – (3) / Pectopexy with reinforcement of the vaginal walls in case of concomitant cystocele and/or rectocele.(4)  | 
| Fixation | – Pectineal ligament: non-absorbable suture – Vaginal stump: absorbable monofilament suture – Cervix: non-absorbable suture (size 0)  | 
| Smooth Warp-Knitted Selvedges | |
| Defined Elasticity | |
| Visible Technology | |
| Materials | 
 – Polyvinylidene fluoride (PVDF) (CAS 24937-79-9) > 99% (w/w) (1) – (4) 
– Phthalocyanine green (CAS 1328-53-6) < 1% (w/w) (1) – (4) – Triiron tetraoxide (CAS 1317-61-9) < 1% (w/w) (2) – (4)  | 
| Polymer (Monofilament) | PVDF | 
| Biocompatibility | |
| Ageing Resistance | |
| Effective Porosity | |
| Klinge’s Mesh Classification | Class 1a [102P, TR121] | 
| Applies to all product sizes | |
| Does not apply | |
| [#] | Reference “#” (see “References”) | 
| [TR#] | Internal test report (see “internal test report references”) | 
| Limitations | “A” animal trial, “B” bench test, “VIT” in-vitro trial, “P” published results based on the analysis of human mesh explants, “PB” published results mainly based on bench tests  |